power sector

Power Sector

Power Sector

Power is a necessary fuel for a growing economy. For the rapid and prolonged growth of the economy, the power sectors in India also need to progress more. For sustained advancement and meeting the future demands of a growing economy, power sector industries must increase their preparedness and enhance their competitiveness. At Shylendra Electronics, we are committed to equipping power sector industries with world-class solutions for design, engineering, testing, and manufacturing.

Generating Plant

Generating Plant

For generating an efficient amount of energy from power plants, all power transformers, generators, and rotating machines need to be fully operational. Therefore in order to keep the systems updated and maintained, they need to be checked and tested frequently and with enhanced precision. For this, we render high accuracy testing kits and measuring instruments and ensure the high performance of power plant machines.

Capacitance and Tan Delta testing kit

Capacitance and Tan Delta testing kit

  • Compact & lightweight ONE piece fully automatic test unit
  • Output voltage up to 12 kV
  • Variable output frequency: 1 to 500 Hz
  • Compensating reactor for generator/motor testing
  • Local control with large graphical display
Relay testing kit

Relay testing kit

  • 6 Current and 4 Voltage generators plus 1 battery simulator outputs
  • Current outputs: 6 x 32 A, 3 x 64 A, 1 x 128 A
  • Voltage outputs: 4 x 300 V at 100 VA.
  • Testing all relay technologies: electromechanical, solid state, numerical and IEC61850.
  • Internal GPS and IRIG-B interface for end-to-end tests
  • Complete library of relays from the major manufacturers
Contact Resistance meter

Contact Resistance meter

  • 100A & 200A Pulsating DC selectable Test Current
  • Dual Grounding Facility
  • Direct mV Drop Reading
  • Resistance Range : 0.1μΩ to 20mΩ, Autoranging
Winding resistance meter

Winding resistance meter

  • Measurement ranges from 2mΩ to 2000Ω w/ resolution of 0.1μΩ
  • 3 independent resistance measuring channels / test current 10A
  • Heat run & Demagnetization test.
  • OLTC Dynamic test with graph: Time Vs Current
Insulation Resistance tester from 1kV to 15kV

Insulation Resistance tester from 1kV to 15kV

  • Wide measurement range from 10 kΩ to 30 TΩ / test voltage from 40V ‐ 15kV
  • 3 filters to optimize measurement stability
  • Automatic calculation of DAR / PI / DD /ΔR (ppm/V) ratios.
  • Large backlit LCD screen with display, bargraph and R(t)+u(t) , i(t) and i(u) graphs
Circuit Breaker test kit

Circuit Breaker test kit

  • ONE single connection set up to automatically perform all possible Circuit Breaker tests
  • Up to 6 static and dynamic contact resistance measurement - 200A DC output each
  • 16 or 24 fully user configurable Main/PIR and auxiliary input contacts
  • Library of standard test plans are available with the test set
Transmission Segment

Transmission Segment

The transmission of electricity is greatly influenced by the voltage distribution across the transmission lines, which can only be achieved with proper voltage control, testing, and monitoring. To attain the ideal electricity transmission, the right equipment is a prerequisite for the organizations.

Partial Discharge Test

Partial Discharge Test

  • One device for GIS & MV Switchgear, HV/MV cables, transformers, rotating machines.
  • Ultra-Wide Band, fast integrated processing capability
  • Multiple Connectivity (Wi-Fi, Fibre Optics, USB, Bluetooth)
  • PD Pulse detector and waveform analyser.
Lorem Ipsum

Portable PD Detector

  • Handheld device and easy to know PD presence
  • Employs 5 types of online PD sensor technologies
  • PRPD, PRPS, Single-Cycle, Phase, Waveform, and Amplitude Spectrums to determine PD types
  • Wireless connection to UHF and HFCT sensors
CT/PT Analyser

CT/PT Analyser

  • Able to test CT with saturation voltage up to 2kV and till 30kV by applying DC indirect method
  • Time saving testing: only 1 set up connection to perform all tests
  • Ratio & Phase Error, Excitation, Resistance, Accuracy, Burden Test will be performed.
  • CT Explorer function: able to find the nameplate data of the CT
Step & Touch and Line impedance Test

Step & Touch and Line impedance Test

  • Hight current output from 1A to 105A
  • performs the measurement of: soil resistivity, ground grid resistance, step and touch tests
  • Short-circuit proof with 25 kAeff / 100 ms; 36 kAeff / 75 ms
Earthing & Short-Circuiting devices

Earthing & Short-Circuiting devices, Voltage detectors

  • Earthing and short-circuiting device available from low voltage to Extra High voltage
  • Volage detectors available from 1Kv to 420Kv
  • Safety tools and accessories are available
Primary injection test kit

Primary injection test kit

  • High current output up to 7000 A
  • Powerful output up to 35 KVA
  • Low voltage breaker testing, CT testing
Distribution

Distribution

Power distribution is an important cluster of industries that include the production of machinery, electric lines and transformers as well as line management systems (such as "smart-grid" technology) that improve efficiency. For providing power to massive infrastructure, streamlined and efficient power distribution is necessary. For enhancing the efficiency of power distribution, we have effective power efficiency solutions and equipment.

Power quality Analyser

Power quality Analyser

  • Full compliance with IEC 61000-4-30 Class A Ed 3, with 4 voltage and 4 current input.
  • Voltage ranges up to 1000V AC/DC.
  • Current measurement will be more than 5000A using clamp.
  • Transient, recording, alarm, true inrush and complete power analysis.
  • Electrical network monitoring with setting of alarms
Insulation Resistance tester

Insulation Resistance tester 1kV to 5kV

  • Insulation resistance measurement upto 11GΩ & 50GΩ at 1kV
  • Backlight visual alarm
  • Test Mode: manual, lock, timer, PI, DAR
Earth tester

Earth tester

  • Measurement starting from 0.001Ω upto 100kΩ
  • For soil resistivity measurements, simply program the distances used for the measurement and the instrument automatically calculates r using the Wenner or Schlumberger methods.
  • Adjustment of the measurement frequency between 41 Hz and 512 Hz (3P & 4P measurements)
  • 5 in 1: Earth • Selective earth• Resistivity • Coupling • Continuity